Tripp Lite SUINT2200RTXL2U Datenblatt Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
Features
SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 3% of200/208/220/230/240V (user selectable) under
all usage condition
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
Corrects line voltage conditions as low as 130V and as high as 275V back to selectable 200/208/220/230/240V (+/-3%) values
Standard internal battery set offers 14 minutes runtime at half load (800W) and 5 minutes at full load (1600W)
Extended Runtime with BP48V24-2U (limit 1) or BP48V60RT3U (multi-pack compatible) external battery packs
Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 483 mm
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and
requires maintenance
Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any
number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current,
battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal
voltage adjustment and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
C20 inlet power connection / C19 and C13 output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (both of the
C19 outlets are individually controllable)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection ofinternal batteries by user required
Single line TEL/DSL or network ethernet line surge suppression
2 year manufacturer's product warranty
Specifications
SYSTEM OVERVIEW
Voltage compatibility 200, 208, 220, 230, 240V (selectable)
Frequency
compatibility
50/60 Hz auto-sensing
OUTPUT
Output VA 2200
Output watts 1600
Output nominal
voltage
200, 208, 220, 230, 240V (selectable)
Output voltage
regulation
Full time sine wave output within 2% of selected nominal, 5% max THD
Output frequency
regulation
Yes, output is locked to 50/60Hz +/-0.05Hz
Outlet quantity / type 4 IEC-C13 & 2 IEC-C19
Customized load
management
receptacles
2 controllable load banks support load shedding and remote reboot on demand of locked network devices (each C19
outlet is individually controllable)
Overload protection 15A input breaker
INPUT
Maximum input amps 9.7A-200V / 9.3A-208V / 8.8A-220V / 8.5A-230V / 8.1A-240V / 1940 watts max.
Seitenansicht 1
1 2 3 4 5 6

Kommentare zu diesen Handbüchern

Keine Kommentare